Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
CavoFerroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavo

Bus Cavo

Serracavi

Data Cable

Calore di rilevamento Cavo
Cavo ad alta temperatura
Cavo autostrada
Marine, petrolio, gas e petrolchimico Cavo
Cavo Speciali
Cavo a spirale
Termocoppia Cavo
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Cavo telefonico

 PE Insulated & PE Sheathed Non Metallic Reinforced Drop Wires to RUS (REA) PE-7

image of PE Insulated & PE Sheathed Non Metallic Reinforced Drop Wires to RUS (REA) PE-7

Applicazione

The drop wires are one or two pair aerial service wires designed for use in extending telephone service to subscriber premises from the cable terminal.

Norme

construction of PE Insulated & PE Sheathed Non Metallic Reinforced Drop Wires to RUS (REA) PE-7

• RUS (REA) PE-7

 

 

Costruzione

Conduttori
Solid annealed bare copper 0.5/0.8mm as per ASTM B-3/IEC 60228 Class 1

Isolamento
Solid polyethylene as per ASTM D 1248/IEC 60708

Cavo Core Assemblea & Core Wrapping
Individual conductors are twisted into pairs and wrapped with PETP tape

Forza di Stato
Aramid yarn as non-metallic strength member is placed inside the sheath to provide longitudinal strength

Guaina
PE is extruded over the core to provide protection against mechanical damage, degradation by sunlight and water ingress

Ripcord
A ripcord made of polyamide is placed parallel to the core to facilitate sheath removal

Proprietà elettriche

Conductor Diameter

mm

0.5

0.8

Conductor Gauge Size

AWG

24

20

Maximum Conductor Resistance @20°C

Ω/km / Ω/mile

91/145.78

34.6/55.72

Minimum Insulation Resistance @500V DC

MΩ.km / MΩ.mile

10000/6214

10000/6214

Maximum Resistance Unbalance

%

2

2

Average Mutual Capacitance @1000Hz

nF/km / nF/kft

55/16.8

55/16.8

Maximum Capacitance Unbalance pair-to-pair

pF/km / pF/kft

300/91

300/91

Maximum Capacitance Unbalance pair-to-ground

pF/km / pF/kft

1000/303.4

1000/303.4

Impedance @0.8KHz

Ω/km / Ω/mile

600/965.6

600/965.6

Impedance @64KHz

Ω/km / Ω/mile

125/201.2

125/201.2

Impedance @772KHz

Ω/km / Ω/mile

100/160.9

100/160.9

Maximum Average Attenuation @0.8KHz

Ω/km / Ω/mile

1.5/2.4

1.5/2.4

Maximum Average Attenuation @64KHz

Ω/km / Ω/mile

8.0/12.87

8.0/12.87

Maximum Average Attenuation @772KHz

Ω/km / Ω/mile

18/28.97

18/28.97

Dielectric Strength 1min

V

1000DC/1500AC

1000DC/1500AC

Proprietà meccaniche e termiche

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 10 x Overall Diameter

Codice colore

  A wire B wire
1 PR White Blue
1 PR Yellow Black

 

 

Dimensioni e peso

Cable Code Number of Pairs Insulation Thickness
mm/inch
Sheath
Thickness
mm/inch
Nominal Overall
Diameter
mm/inch
Nominal Weight
kg/km / lbs/kft
0.5mm Conductor, 0.9mm Insulated Wire
TP7-2Y2Y-2P05-SS-A 2 0.2/0.0079 1.2/0.047 5.0/0.197 26.2/17.6
0.8mm Conductor, 1.36mm Insulated Wire
TP7-2Y2Y-1P08-SS-A 1 0.28/0.0110 1.2/0.047 5.3/0.209 26.6/17.9